Ryurei™
PTCA Dilatation Catheter
Ryurei™ has superior crossability thanks to the combination of low distal profiles and Terumo's hydrophilic Mcoat™.
The short balloon bonding and reinforced shaft results in enhanced trackability while maintaining excellent pushability.
Confidence in your hands
Ryurei™ has superior crossability thanks to the combination of low distal profiles and Terumo's hydrophilic Mcoat™. The short balloon bonding and reinforced shaft results in enhanced trackability while maintaining excellent pushability.
Product Details
Developed to create “a balloon that can support the procedure under any therapeutic conditions”
Ryurei™ achieves smooth trackability and powerful crossability in complicated lesions by using a flexible material for the tip and adopting a core wire structure.
Tip
A small entry profile of 0.41 mm. (Φ1.00 - Φ1.50mm)
Like Tazuna™, the tip is made of a flexible material.
Balloon
1.00mm - the smallest diameter* for a balloon
-A 1.00 mm diameter balloon is included in the lineup, facilitating
manipulation in severely stenotic lesions.
Re-wrappable structure
- Three pleats (2.25 mm - 4.00 mm diameter)
Shaft : Core wire structure
The conventional spiral-cut structure used from the proximal end to the tip of the shaft in existing balloons was re-engineered, switching to a core wire structure.
Accuforce™
PTCA Dilatation Catheter
The great balance between high pressure and high resistance, accurate dilatation and advanced deliverability.
Accuforce™ is the latest generation of non-compliant PTCA balloons.
Force. Success. No Compromise
The great balance between high pressure and high resistance, accurate dilatation and advanced deliverability.
Accuforce™ is the latest generation of non-compliant PTCA balloons.
Product Details
Optimise (re) crossability and deliverability
Soft balloon material and newly designed radiopaque markers improve flexibility.
Reinforcement of the guidewire exit port structure enhances the durability of the shaft and forces transmission from the proximal shaft to the distal tip for advanced
pushability.
Low profile shaft and guidewire exit port enable the kissing balloon technique with a 6 Fr lumen guiding catheter.
Provide impressive high-pressure resistance up to 22 atm
The innovative triple layer technology of Accuforce™ consists of:
Soft inner/outer elastomer layers offering resistance to high pressure from the
inside and against damage to the outside.
Stronger middle layer in polyamide, which provides an additional and safer
high pressure resistance required for severe calcified lesions.
Be accurate in pre & post-dilatation
The additional elastomer layer compared to a traditional double layer balloon structure provides safer high-pressure dilatation with low compliance.
Shorter and rounded balloon shoulders only target lesions and the stent for effective and focused dilatation as it is necessary for the Proximal Optimization Technique (POT)
in bifurcations.